欧美日韩在线视频,欧美亚洲日本国产,97久久超碰日韩精品,天天干夜夜想

歡迎進(jìn)入濟(jì)南濟(jì)柴環(huán)能燃?xì)獍l(fā)電設(shè)備有限公司官網(wǎng)!
當(dāng)前位置:首頁 - 新聞中心 - 發(fā)電機(jī)知識

發(fā)電機(jī)知識

發(fā)電機(jī)組在安裝時需要注意的六大要點

返回 2022.08.26 來源:http://www.vw95.cn 0
本文將為大家簡單的介紹關(guān)于焦化發(fā)電機(jī)組在安裝時須注意的六個要點,一起來看看看吧。
This article will briefly introduce the six points that should be paid attention to when installing the coking generator set. Let's have a look.
1、安裝地點需通風(fēng)良好,發(fā)電機(jī)端應(yīng)有足夠的進(jìn)風(fēng)口,焦化機(jī)端應(yīng)有良好的出風(fēng)口。出風(fēng)口面積應(yīng)大于水箱面積1.5倍以上。
1. The installation site shall be well ventilated. There shall be sufficient air inlets at the generator end and good air outlets at the coking machine end. The air outlet area shall be more than 1.5 times of the water tank area.
2、安裝地的周圍應(yīng)保持清潔,避免在附近放置能產(chǎn)生酸性、堿性等腐蝕性氣體和蒸汽的物品。有條件的應(yīng)配置滅火裝置。
2. The surroundings of the installation site shall be kept clean, and articles that can generate corrosive gases and vapors such as acid and alkaline shall be avoided from being placed nearby. Fire extinguishing devices shall be provided if conditions permit.
3、在室內(nèi)使用,須將排煙管道通導(dǎo)室外,焦化發(fā)電機(jī)管徑須≥消音器的出煙管直徑,所接之管路的彎頭不宜超過3個,以保證排煙暢通,并應(yīng)將管子向下傾斜5-10度,避免雨水注入;若排氣管時垂直向上安裝的,則須加裝防雨罩。
3. For indoor use, the smoke exhaust pipe must be connected to the outside. The pipe diameter of the coking generator must be ≥ the diameter of the exhaust pipe of the silencer. The elbows of the connected pipes should not be more than 3 to ensure smooth smoke exhaust. The pipes should be inclined downward by 5-10 degrees to avoid rainwater injection; If the exhaust pipe is installed vertically, a rain cover must be installed.
焦化發(fā)電機(jī)組
4、基礎(chǔ)采用混凝土?xí)r,在安裝時須用水平尺測其水平度,使機(jī)組固定于水平的基礎(chǔ)上。機(jī)組與基礎(chǔ)之間應(yīng)有專用防震墊或用底腳螺栓。
4. When the foundation is made of concrete, the levelness shall be measured with a level ruler during installation to fix the unit on the horizontal foundation. There shall be special shockproof pads or foot bolts between the unit and the foundation.
5、機(jī)組外殼須有可靠的保護(hù)接地,對需要有中性點直接接地的發(fā)電機(jī),則須由人員進(jìn)行中性接地,并配置防雷裝置,嚴(yán)禁利用市電的接地裝置進(jìn)行中性點直接接地。
5. The unit shell must have reliable protective grounding. For the generator that needs to be directly grounded at neutral point, the neutral grounding shall be conducted by professional personnel and equipped with lightning protection device. It is strictly prohibited to use the grounding device of mains power for direct grounding at neutral point.
6、發(fā)電機(jī)與市電的雙向開關(guān)須十分可靠,以防倒送電。雙向開關(guān)的接線可靠性需經(jīng)過當(dāng)?shù)毓╇姴块T的檢驗認(rèn)可。
6. The two-way switch between the generator and the mains must be very reliable to prevent reverse power transmission. The wiring reliability of the two-way switch shall be inspected and approved by the local power supply department.
發(fā)電機(jī)組在安裝時需要注意的六大要點上述已經(jīng)講解完畢了,希望能夠給您好的幫助,更多事項就來我們網(wǎng)站http://www.vw95.cn咨詢吧!
The six main points that should be paid attention to during the installation of the generator set have been explained. I hope you can help me. For more matters, please visit our website http://www.vw95.cn Consult!
新聞搜索
濟(jì)南濟(jì)柴環(huán)能燃?xì)獍l(fā)電設(shè)備有限公司
  • 服務(wù)熱線

    0531-62325028
    0531-69951266

發(fā)電機(jī)組在安裝時需要注意的六大要點

本文將為大家簡單的介紹關(guān)于焦化發(fā)電機(jī)組在安裝時須注意的六個要點,一起來看看看吧。
This article will briefly introduce the six points that should be paid attention to when installing the coking generator set. Let's have a look.
1、安裝地點需通風(fēng)良好,發(fā)電機(jī)端應(yīng)有足夠的進(jìn)風(fēng)口,焦化機(jī)端應(yīng)有良好的出風(fēng)口。出風(fēng)口面積應(yīng)大于水箱面積1.5倍以上。
1. The installation site shall be well ventilated. There shall be sufficient air inlets at the generator end and good air outlets at the coking machine end. The air outlet area shall be more than 1.5 times of the water tank area.
2、安裝地的周圍應(yīng)保持清潔,避免在附近放置能產(chǎn)生酸性、堿性等腐蝕性氣體和蒸汽的物品。有條件的應(yīng)配置滅火裝置。
2. The surroundings of the installation site shall be kept clean, and articles that can generate corrosive gases and vapors such as acid and alkaline shall be avoided from being placed nearby. Fire extinguishing devices shall be provided if conditions permit.
3、在室內(nèi)使用,須將排煙管道通導(dǎo)室外,焦化發(fā)電機(jī)管徑須≥消音器的出煙管直徑,所接之管路的彎頭不宜超過3個,以保證排煙暢通,并應(yīng)將管子向下傾斜5-10度,避免雨水注入;若排氣管時垂直向上安裝的,則須加裝防雨罩。
3. For indoor use, the smoke exhaust pipe must be connected to the outside. The pipe diameter of the coking generator must be ≥ the diameter of the exhaust pipe of the silencer. The elbows of the connected pipes should not be more than 3 to ensure smooth smoke exhaust. The pipes should be inclined downward by 5-10 degrees to avoid rainwater injection; If the exhaust pipe is installed vertically, a rain cover must be installed.
焦化發(fā)電機(jī)組
4、基礎(chǔ)采用混凝土?xí)r,在安裝時須用水平尺測其水平度,使機(jī)組固定于水平的基礎(chǔ)上。機(jī)組與基礎(chǔ)之間應(yīng)有專用防震墊或用底腳螺栓。
4. When the foundation is made of concrete, the levelness shall be measured with a level ruler during installation to fix the unit on the horizontal foundation. There shall be special shockproof pads or foot bolts between the unit and the foundation.
5、機(jī)組外殼須有可靠的保護(hù)接地,對需要有中性點直接接地的發(fā)電機(jī),則須由人員進(jìn)行中性接地,并配置防雷裝置,嚴(yán)禁利用市電的接地裝置進(jìn)行中性點直接接地。
5. The unit shell must have reliable protective grounding. For the generator that needs to be directly grounded at neutral point, the neutral grounding shall be conducted by professional personnel and equipped with lightning protection device. It is strictly prohibited to use the grounding device of mains power for direct grounding at neutral point.
6、發(fā)電機(jī)與市電的雙向開關(guān)須十分可靠,以防倒送電。雙向開關(guān)的接線可靠性需經(jīng)過當(dāng)?shù)毓╇姴块T的檢驗認(rèn)可。
6. The two-way switch between the generator and the mains must be very reliable to prevent reverse power transmission. The wiring reliability of the two-way switch shall be inspected and approved by the local power supply department.
發(fā)電機(jī)組在安裝時需要注意的六大要點上述已經(jīng)講解完畢了,希望能夠給您好的幫助,更多事項就來我們網(wǎng)站http://www.vw95.cn咨詢吧!
The six main points that should be paid attention to during the installation of the generator set have been explained. I hope you can help me. For more matters, please visit our website http://www.vw95.cn Consult!